ETOPA team commissioning an industrial installation at the control cabinet

ETOPA / Municipal utilities

Automation for borehole pumps and municipal water systems.

We provide automation, controls and commissioning for borehole pumps and water and wastewater systems. We integrate pumps, valves and instrumentation with the PLC program and operation through HMI or SCADA.

Over25years

in industrial automation

Dozens of plants

rely on our installations in their daily operations

Older and latest technologies

We program, modernise and service both older and newer automation systems.

Processes and equipment

Controls for water abstraction, pumping stations and tanks

We start by assessing the installation: pump and motor type, hydraulic conditions, available measurements and existing protection devices. Settings, interlocks and restart conditions are established for the individual site using equipment documentation and operating requirements.

  • Borehole pumps and water abstraction

    We develop pump start and stop controls to match demand and agreed operating conditions. We check level, pressure and flow signals where available, together with the interfaces to pump and motor protection devices.

  • Pumping stations and tanks

    We program tank filling or draining, pump operating sequences and fault responses. For systems with several pumps, we agree duty alternation and standby pump starting arrangements, taking account of the installation capabilities.

  • Operation and system supervision

    HMI or SCADA screens show available measurements, pump states and the reasons for interlocks. We develop operating modes, trends and alarms and check how the controls respond to loss of a measurement signal or communication.

Scope of support

Automation services for municipal utilities

Discuss the scope
01

PLC programming

Pump, valve and tank controls. Operating modes, start permissives, sequences and interlocks matched to the water and wastewater installation.

Siemens · Schneider · Telemecanique
02

Variable frequency drives

Pump drive parametrisation and diagnostics. Checks of drive and motor compatibility and the permitted control conditions according to pump documentation and hydraulic requirements.

Danfoss · Siemens · Mitsubishi · SEW
03

HMI and SCADA

Visualisation of water abstraction systems, pumping stations and tanks. Device status screens, measurements, settings, trends and alarms tailored to site operation.

Process operation and diagnostics
04

Machine modernisation

Modernisation of existing pump control systems. Assessment of equipment and signals, program preparation and agreement on changeover stages and tests.

Control system retrofits
05

Automation service

Diagnostics of controllers, measurement signals, communication and drives. Investigation of start interlocks, shutdowns and incorrect operation of the controls.

On site and remotely

Before work begins

What information should you prepare about the pumps and installation?

Describe the site, its current controls and the planned change or fault symptoms. Pump, motor and installation data help establish the automation scope and commissioning conditions.

Information needed to define the scope

  • Pump type, motor data and drive details, where applicable
  • Hydraulic diagram and available electrical documentation
  • List of level, pressure and flow measurements and existing protection devices
  • PLC and HMI or SCADA type, available program and connection documentation
  • Required operating modes, fault handling arrangements and possible shutdown window
Discuss your project

Questions about working with us

Before commissioning the work

Can controls be developed for an existing borehole pump?

We check the pump type, motor, existing controls and available signals. We then establish the starting or speed control method and the measurements and protection required, including dry-running protection. Protection functions must use suitable devices or verified signals; their settings are selected for the particular pump and installation.

What do you check when commissioning pumping station controls?

We agree a test plan covering measurement readings, ready, running and fault signals, start permissives and interlocks. We check operating modes and the response to signal or communication loss. Test methods and restart conditions are agreed with site operators, taking account of equipment documentation and hydraulic conditions.

What information do you need before quoting for the work?

We need the site location and description, pump and motor designations, available drawings and details of the controls. A measurement and alarm list, a description of fault symptoms or the intended change, and opportunities for testing are also useful. We agree the automation, controls and commissioning scope after assessing the installation.

Contact ETOPA

Controls for a borehole pump or municipal water system?

Describe the water abstraction site, pumping station or water and wastewater system. Include its location, pump type, current controls and planned changes. We will agree the automation work and commissioning conditions.

Write to us
Konrad Jabłoński+48 725 998 471
Hieronim Jabłoński+48 607 688 804
kontakt@etopa.pl

Poland and abroad

We work across Poland.

We work throughout Poland. We have completed projects in Poland and abroad. We agree the scope, travel arrangements and schedule before work begins. Automation diagnostics over VPN are coordinated with the maintenance team.

Service area: all 16 Polish provinces
Discuss the work +48 725 998 471